GS-11 Standard for Paints, Coatings, Stains, and Sealers · Edition 4.1 · 101 requirements
Read this standard- 4.1.16.6Exterior lacquer wear resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.16.8Exterior lacquer UV resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.17Benchmark performance alternativeKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: an alternative route: matching or beating a comparable benchmark product on key functions.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.2.1.1Exterior concrete adhesionKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 14·No CMF area
- 4.1.2.1.2Exterior flow and levellingKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: flow, levelling, foaming and spatter performance, or a drawdown alternative.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 15·No CMF area
- 4.1.2.2.1Exterior topcoat fade resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13·No CMF area
- 4.1.2.2.3Exterior topcoat water resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: no wash-off, lifting or wrinkling in a water exposure test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 14·No CMF area
- 4.1.3.1.2Floor paint flow and levellingKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.2Floor paint levelling ratingKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.3Floor paint film thickness limitKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.4Floor paint alkali resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.5Floor paint abrasion resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.2.1Floor paint fade resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.4.1Floor coating dry adhesion on concreteKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.15·No CMF area
- 4.1.4.2Floor coating abrasion weight lossKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.15·No CMF area
- 4.1.4.3Floor coating slip resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.15·No CMF area
- 4.1.4.4Floor coating water and salt resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: no damage after seven days in water, plus salt solution for vehicle-traffic products.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.15·No CMF area
- 4.1.4.5Floor coating chemical resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: matching a benchmark product against most of at least seven test chemicals.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.15·No CMF area
- 4.1.4.6Hot tyre resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.15·No CMF area
- 4.1.5.1Anti-corrosive coating adhesionKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.15; 16; 18·No CMF area
- 4.1.5.2Anti-corrosive coating flow and levellingKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: flow, levelling, foaming and spatter performance, or a drawdown alternative.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 15; 16·No CMF area
- 4.1.5.3Anti-corrosive rust resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.16·No CMF area
- 4.1.6.1Reflective wall coating adhesionKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.16·No CMF area
- 4.1.6.1Adhesion on concrete substratesKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.16·No CMF area
- 4.1.6.3Reflective wall coating weatheringKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.16·No CMF area
- 4.1.6.4Reflective wall coating flexibilityKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: no cracking, peeling or adhesion loss in a bend test after set curing.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 14; 16·No CMF area
- 4.1.6.5Reflective wall coating solar reflectanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.16·Climate Health
- 4.1.6.5Solar reflectance thresholdsKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: meeting tabulated solar reflectance values using a listed test method.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.16; 17·Climate Health
- 4.1.6.6Reflective wall coating thermal emittanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.16; 17·Climate Health
- 4.1.6.7Reflective wall coating opacityKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 14; 16·No CMF area
- 4.1.7.1Minimum dry film thicknessKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.17·No CMF area
- 4.1.7.2Accelerated weathering, 1,000 hoursKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.17·No CMF area
- 4.1.7.3Stretch and tensile strength minimumsKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.17·No CMF area
- 4.1.7.4Low-temperature flexibilityKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.17·No CMF area
- 4.1.7.5Fungal growth resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: zero fungal growth rating in a standard test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.17·No CMF area
- 4.1.8.1Physical properties per coating specificationKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: meeting the physical property requirements of a named ASTM coating specification.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.17·No CMF area
- 4.1.8.3Thermal emittance, 80%Klar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.17·Climate Health
- 4.1.9.2Flow and levelling performanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: flow, levelling, foaming and spatter performance, or a drawdown alternative.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.9.2Flow and levelling performanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: flow, levelling, foaming and spatter performance, or a drawdown alternative.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.9.3Fire resistance matching labelKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: a fire resistance rating consistent with label claims, by standard fire test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.9.4Class A flame spread and smokeKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: Class A indices for flame spread and smoke in a surface burning test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.2.1Consumer use informationKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: guidance for buyers on quantity, ventilation, proper use and related matters.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·Circular Economy
- 4.2.12.2.3Film adhesion 3B after curingKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.2.2Disposal and recycling statement on labelKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: label advice to consult local authorities on disposing or recycling leftover product.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·Circular Economy
- 5.1Certification mark useKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: using the certifier's mark and name only as its trademark guidelines allow.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.22·No CMF area
- 5.2Misleading certification claimsKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: no wording or images with the mark that overstate the certification.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.22·No CMF area
- clause not recordedException for titanium dioxide, carbon blackKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.8·Human Health
- clause not recordedCrystalline silicaKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: no deliberately added free crystalline silica; natural traces in minerals are excluded.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.8·Human Health
- clause not recordedWater supply contaminants exclusionKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: naturally occurring elements and chlorination by-products below drinking water limits not counted as ingredients.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.8·Human Health
- clause not recordedPCBTF allowance in metal lacquersKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.9·Human Health