Green Seal
113 requirements in the product view, of 113 held for this scheme. Scheme profile
Wording is not listed. Open the clause for its citation and, where the publisher’s terms allow, its words.
GS-11 Standard for Paints, Coatings, Stains, and Sealers · Edition 4.1 · 79 requirements
Read this standard- 4.1.1.1.1Wall and ceiling coating adhesionKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: pull-off adhesion on concrete and tape adhesion on other substrates, wet and dry.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.12·No CMF area
- 4.1.1.1.2Wall and ceiling coating flow and levellingKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: flow, levelling, foaming and spatter performance, or a drawdown test alternative.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.12; 13·No CMF area
- 4.1.1.2.1Scrub resistance of interior topcoatsKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.12; 13·No CMF area
- 4.1.1.2.2Stain removal for interior topcoatsKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: minimum stain removal ratings, higher for non-flat than flat topcoats.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13·No CMF area
- 4.1.1.4Impact resistance versus benchmarkKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: impact-resistant products performing at least as well as a benchmark in their class.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13·No CMF area
- 4.1.10.1Sealer testing of claimed propertiesKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: concrete and masonry sealers tested for every performance property they claim, except basement coatings.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.1Sealer water resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: showing water resistance using a listed masonry or concrete test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.2Sealer fungi resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: showing resistance to fungal growth using listed test methods.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.3Sealer abrasion resistance and concrete hardeningKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: how well a sealer hardens concrete and resists wear, by a standard abrasion test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.4Sealer alkali resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: showing resistance to alkali by a spot test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.5Sealer acid resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: showing resistance to acid by a spot test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.6Sealer stain resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: showing resistance to staining by a spot test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.7Sealer UV resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: showing resistance to ultraviolet light in an accelerated exposure test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.1.8Sealer water vapour transmissionKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: measuring how much water vapour passes through the sealer.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.18·No CMF area
- 4.1.10.2.1Withstanding hydrostatic water pressureKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.10.2.2Mould and mildew resistance ratingKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.11.2Blush resistance, minimum rating 8Klar Cite’s name
Klar Cite note, not the standard’s words: Addresses: whitening resistance of a thin dry film after two hours in a water exposure test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.11.3Covered spot chemical resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.12.1.1Blush resistance, minimum rating 8Klar Cite’s name
Klar Cite note, not the standard’s words: Addresses: whitening resistance of a thin dry film after two hours in a water exposure test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.12.2.1Blush resistance, minimum rating 7Klar Cite’s name
Klar Cite note, not the standard’s words: Addresses: whitening resistance of a thin dry film after two hours in a water exposure test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.12.2.2Pencil hardness 2HKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19; 20·No CMF area
- 4.1.13.1Pencil hardness 2HKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.13.2Covered spot chemical resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19; 20·No CMF area
- 4.1.13.3Film adhesion 4B after curingKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19; 20·No CMF area
- 4.1.13.4Water repellency of waterproofing sealersKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.19·No CMF area
- 4.1.14.2Drying time limitKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: the coating becoming dry to touch within four hours.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.14.4Blistering under condensationKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.14.5Water repellency of waterproofing sealersKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.15.3Surface hardness 3HKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.15.4Humidity resistance, 48 hoursKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.15.5Salt spray resistance, 24 hoursKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.15.6Wear resistance by falling abrasiveKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.15.7Removability with acetoneKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20; 21·No CMF area
- 4.1.15.8Resistance to perspirationKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: withstanding at least two cycles of the hardware industry perspiration test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.16.2Surface hardness 3HKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.20·No CMF area
- 4.1.16.3Exterior clear metal lacquer humidity resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.16.4Exterior lacquer chemical resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.16.5Exterior lacquer salt spray resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.16.6Exterior lacquer wear resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.16.8Exterior lacquer UV resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.17Benchmark performance alternativeKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: an alternative route: matching or beating a comparable benchmark product on key functions.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.21·No CMF area
- 4.1.2.1.1Exterior concrete adhesionKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 14·No CMF area
- 4.1.2.1.2Exterior flow and levellingKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: flow, levelling, foaming and spatter performance, or a drawdown alternative.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 15·No CMF area
- 4.1.2.2.1Exterior topcoat fade resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13·No CMF area
- 4.1.2.2.3Exterior topcoat water resistanceKlar Cite’s name
Klar Cite note, not the standard’s words: Addresses: no wash-off, lifting or wrinkling in a water exposure test.
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.13; 14·No CMF area
- 4.1.3.1.2Floor paint flow and levellingKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.2Floor paint levelling ratingKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.3Floor paint film thickness limitKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.4Floor paint alkali resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area
- 4.1.3.1.5Floor paint abrasion resistanceKlar Cite’s name
GS-11 Standard for Paints, Coatings, Stains, and Sealers·p.14·No CMF area