Emissions of COD from wet processes
Mandatory
Required: must be met for the credential.
Klar Cite summary
Wet processes in panel production must emit no more than 20 g of chemical oxygen demand per kg of product to water, measured unfiltered. Evidence the scheme asks for: measurement results including information on sampling programmes and measurement methods for the past 12 months and measurement frequency. This concerns ecosystems and nature.
Nordic Swan·clause O38·p.35
Ecosystem Health
Original wording
The publisher lets each reader see 11 of this document’s clauses a day when signed in, or 5 without signing in.
This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.
Details
How it is proven
- Evidence required
- Measurement results including information on sampling programmes and measurement methods for the past 12 months and measurement frequency.
- Who checks it
- Independent body verifies — a certifier, auditor or verifier with no stake
Klar Cite’s reading
Klar Cite’s reading of the clause, not the scheme’s own claim.
- Type of requirement
- Meet a limit or condition — e.g. a maximum emission or a minimum recycled content
- Standing
- Required — must be met for the credential
- Topic
- Ecosystem Health — the topic the clause addresses, grouped by the Common Materials Framework (CMF)
- Refers to
- Appendix 1 — places elsewhere in the document
Cite this clause
Nordic Swan · Exterior Panels And Cladding (114) · version Group 114 v2.1 · clause O38 · page 35 · build 2026-10-27-1239 · https://klarcite.com/r/bbeab5d903ee4700
Record details
Page 35. Read in build 2026-10-27-1239, harvested 2026-10-27.
uid bbeab5d903ee4700 · document a6ebfe6864a46308 · fidelity verbatim · publication date not recorded