Floor coverings and underlays must keep emissions within tabulated limits, tested on the final product after 28 days to EN 16516 or ISO 16000-9. Evidence the scheme asks for: analysis report. An independent assessor checks it. This concerns human health.

Nordic Swan·clause O41·pp.43-44

Human Health

Original wording

The publisher lets each reader see 10 of this document’s clauses a day when signed in, or 5 without signing in.

This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.

Details

What the product must meet

The document’s own listing

Bamboo flooring, cork flooring/cork tile flooring and cork-based underlays: TVOC 0.3 mg/m3, SVOC 0.03 mg/m3, Formaldehyde 0.06 mg/m3, Carcinogenic VOC in category 1A and 1B 0.001 mg/m3 Solid wood flooring: TVOC 0.3 mg/m3, SVOC 0.03 mg/m3, Formaldehyde 0.06 mg/m3, Carcinogenic VOC in category 1A and 1B 0.001 mg/m3 Multi-layer wood flooring and wood veneer flooring: TVOC 0.3 mg/m3, SVOC 0.03 mg/m3, Formaldehyde 0.06 mg/m3, Carcinogenic VOC in category 1A and 1B 0.001 mg/m3 Multilayer modular flooring, hybrid flooring and other underlays: TVOC 0.2 mg/m3, SVOC 0.02 mg/m3, Formaldehyde 0.01 mg/m3, Carcinogenic VOC in category 1A and 1B 0.001 mg/m3 Laminate flooring: TVOC 0.1 mg/m3, SVOC 0.02 mg/m3, Formaldehyde 0.03 mg/m3, Carcinogenic VOC in category 1A and 1B 0.001 mg/m3 Linoleum flooring: TVOC 0.2 mg/m3, SVOC 0.03 mg/m3, Formaldehyde 0.01 mg/m3, Carcinogenic VOC in category 1A and 1B 0.001 mg/m3 Plastic flooring and plastic underlays: TVOC 0.1 mg/m3, SVOC 0.02 mg/m3, Formaldehyde 0.01 mg/m3, Carcinogenic VOC in category 1A and 1B 0.001 mg/m3

The document’s own compact listing of the limits, as harvested.

How it is proven

Evidence required
Analysis report, including measurement methods, results, and measurement frequency.
Who checks it
Independent body verifies — a certifier, auditor or verifier with no stake

Klar Cite’s reading

Klar Cite’s reading of the clause, not the scheme’s own claim.

Type of requirement
Meet a limit or condition — e.g. a maximum emission or a minimum recycled content
Standing
Required — must be met for the credential
Topic
Human Health — the topic the clause addresses, grouped by the Common Materials Framework (CMF)

Cite this clause

Nordic Swan · Floor Coverings (029) · version Group 029 v7.3 · clause O41 · page 43-44 · build 2026-10-27-1239 · https://klarcite.com/r/7366a21026f3aa7b

Source document

Record details

Page 43-44, 1.7.1 Emission. Read in build 2026-10-27-1239, harvested 2026-10-27.

uid 7366a21026f3aa7b · document 80398fbdf4e8f5cb · fidelity verbatim · publication date not recorded

See all clauses in this standard