Quantity of applied volatile organic compounds (VOC)

Mandatory

Required: must be met for the credential.

Klar Cite summary

Each surface treatment system must contain no more than 5% VOC by weight, or apply no more than 10 g/m2 of VOC to the treated surface. Evidence the scheme asks for: safety data sheet for each chemical product used in the surface treatment system in compliance with current European legislation No. 1907/2006. This concerns human health.

Nordic Swan·clause O37·p.35

Human Health

Limit
≤ 5 %

Original wording

The publisher lets each reader see 11 of this document’s clauses a day when signed in, or 5 without signing in.

This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.

Details

What the product must meet

Limits held for this clause

Parameter / contextOperatorLimitUnit
m: a) The total VOC content must not exceed 5% by weight, or b) The total amount of VO≤5%
otal amount of VOCs applied must not exceed 10 g/m2 treated surface.≤10g/m2

The document states how these relate: any one of these limits is accepted.

Compare this limit across schemes

The limit was read from the clause wording.

How it is proven

Evidence required
Safety data sheet for each chemical product used in the surface treatment system in compliance with current European legislation (Annex II of REACH, Regulation (EC) No. 1907/2006). Declaration from the manufacturer/supplier of the chemical products in the surface treatment system, detailing the quantity of VOCs in each product. A calculation from the performer of the surface treatment showing that alternative b) in the requirement is met if the surface treatment system does not meet alternative a).
Who checks it
Independent body verifies — a certifier, auditor or verifier with no stake

Klar Cite’s reading

Klar Cite’s reading of the clause, not the scheme’s own claim.

Type of requirement
Meet a limit or condition — e.g. a maximum emission or a minimum recycled content
Standing
Required — must be met for the credential
Topic
Human Health — the topic the clause addresses, grouped by the Common Materials Framework (CMF)

Cite this clause

Nordic Swan · Exterior Panels And Cladding (114) · version Group 114 v2.1 · clause O37 · page 35 · build 2026-10-27-1239 · https://klarcite.com/r/699a281b33139f47

Source document

Record details

Page 35. Read in build 2026-10-27-1239, harvested 2026-10-27.

uid 699a281b33139f47 · document a6ebfe6864a46308 · fidelity verbatim · publication date not recorded