Classification of chemical products

Mandatory

Required: must be met for the credential.

Klar Cite summary

Chemical products used to make the floor covering, surface treatments included, must not carry any of the hazard classifications the criteria list. Evidence the scheme asks for: a declaration from the chemical manufacturer or supplier, in accordance with Appendix 6. This relates mainly to human health.

Nordic Swan·clause O25·pp.32-33

Human Health

Limit
≤ 10 %
Exemption
Exemptions apply for: • Classification H351 for adhesive products containing methylene diphenyl diisocyanate (MDI). Isocyanates used in the production of polyurethane material such as polyurethane foam are regulated in separate requirement O36. • Classifications H350, H341, H301, H311 and H331 for adhesive products and resins containing formaldehyde (CAS No. 50-00-0). Formaldehyde emissions are regulated in requirements O31 and O41. • Classifications H341, H301 and H331 for resins containing a maximum of 10% by weight of phenol (CAS No. 108-95-2). • Classifications H301, H311, H331 and H370 for resins containing a maximum of 10% by weight of methanol (CAS No. 67-56-1). • Classifications H351 and H361 for resins containing melamine (CAS No. 108-78-1). • Classifications H400 and H410 for accelerators for linoleum production in amounts up to 1 percent of the linoleum. • UV curing surface treatment products classified as environmentally hazardous if UV curing surface treatment products are applied to the material during a controlled closed process where no discharge to recipient takes place. Spills and residual waste (e.g., residues from cleaning) must be collected in containers that are approved for hazardous waste and handled by a waste contractor. • The hardener in two-component paint/varnish/filler products can be exempted for classifications as toxic to the environment and/or carcinogenic, germ cell mutagenic and/or reproductive toxicity in category 2, if the following is met: it must be documented that the workers are not exposed to the components, e.g., by using safety equipment when mixing or that the mixing takes place automatically without exposure of the workers and that the application of the finished two-component system is done in a closed system.

Original wording

The publisher lets each reader see 10 of this document’s clauses a day when signed in, or 5 without signing in.

This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.

Details

What the product must meet

Limits held for this clause

Parameter / contextOperatorLimitUnit
share≤10%

The clause carries more than one limit; only the first is held as a number.

Compare this limit across schemes

The limit was read from the clause wording.

The document’s own listing

Toxic to the environment: Aquatic Acute 1, Aquatic Chronic 1, Aquatic Chronic 2 (H400, H410, H411) Hazardous to the ozone layer: Ozone (H420) Acute toxicity: Acute Tox 1 or 2 (H300, H310, H330); Acute Tox 3 (H301, H311, H331) Specific target organ toxicity – single exposure/repeated exposure: STOT SE 1, STOT RE 1 (H370, H372) Carcinogenic: Carc. 1A or 1B, Carc. 2 (H350, H351) Germ cell mutagenic: Mut. 1A or 1B, Mut. 2 (H340, H341) Reproductive toxicity: Repr. 1A or 1B, Repr. 2, Lact. (H360, H361, H362) Including all combinations of stated exposure route and stated specific effect. For example, H350 also covers the classification H350i. Note that responsibility for correct classification lies with the manufacturer.

The document’s own compact listing of the limits, as harvested.

Exemptions
Exemptions apply for: • Classification H351 for adhesive products containing methylene diphenyl diisocyanate (MDI). Isocyanates used in the production of polyurethane material such as polyurethane foam are regulated in separate requirement O36. • Classifications H350, H341, H301, H311 and H331 for adhesive products and resins containing formaldehyde (CAS No. 50-00-0). Formaldehyde emissions are regulated in requirements O31 and O41. • Classifications H341, H301 and H331 for resins containing a maximum of 10% by weight of phenol (CAS No. 108-95-2). • Classifications H301, H311, H331 and H370 for resins containing a maximum of 10% by weight of methanol (CAS No. 67-56-1). • Classifications H351 and H361 for resins containing melamine (CAS No. 108-78-1). • Classifications H400 and H410 for accelerators for linoleum production in amounts up to 1 percent of the linoleum. • UV curing surface treatment products classified as environmentally hazardous if UV curing surface treatment products are applied to the material during a controlled closed process where no discharge to recipient takes place. Spills and residual waste (e.g., residues from cleaning) must be collected in containers that are approved for hazardous waste and handled by a waste contractor. • The hardener in two-component paint/varnish/filler products can be exempted for classifications as toxic to the environment and/or carcinogenic, germ cell mutagenic and/or reproductive toxicity in category 2, if the following is met: it must be documented that the workers are not exposed to the components, e.g., by using safety equipment when mixing or that the mixing takes place automatically without exposure of the workers and that the application of the finished two-component system is done in a closed system.

How it is proven

Evidence required
A declaration from the chemical manufacturer or supplier, in accordance with Appendix 6. A safety data sheet for the product in compliance with current European legislation (Annex II of REACH, Regulation (EC) No. 1907/2006). Exemption for UV curing surface treatment products: Description of the process and how waste and residual waste are handled, including information about who receives the wastes. Exemption for two-component paint/varnish/filler products: description of the mixing and the application system and how employees are protected from exposure.
Who checks it
Independent body verifies — a certifier, auditor or verifier with no stake

Klar Cite’s reading

Klar Cite’s reading of the clause, not the scheme’s own claim.

Type of requirement
Meet a limit or condition — e.g. a maximum emission or a minimum recycled content
Standing
Required — must be met for the credential
Topic
Human Health — the topic the clause addresses, grouped by the Common Materials Framework (CMF)

Cite this clause

Nordic Swan · Floor Coverings (029) · version Group 029 v7.3 · clause O25 · page 32-33 · build 2026-10-27-1239 · https://klarcite.com/r/1ed2a7ad3de62868

Source document

Record details

Page 32-33, 1.5.1 Chemicals. Read in build 2026-10-27-1239, harvested 2026-10-27.

uid 1ed2a7ad3de62868 · document 80398fbdf4e8f5cb · fidelity close quote · publication date not recorded

See all clauses in this standard