Ratings & Policy

Find where a product credential earns points or counts, and what each rating tool or policy accepts.

Pick any rating tools or policies and any credentials. The results narrow to what you pick.

5 credentials, in Homestar v5 and WELL v2. Clear selection

EMICODE

Where it earns points or counts, rating tool by rating tool. About EMICODE

Credit names, credential names and conditions are in each rating tool's or policy's own words, shown where its publisher's terms allow.

Homestar v5Rating tool

  • HC7 Healthy Materials, method (4) adhesives and sealants; Recognised list, Indoor Air Quality Schemes row

    Status
    Accepted with conditions
    Named as
    EMICODE
    Edition named
    Not stated by the tool
    On what basis
    product within the VOC limits set by the recognised IAQ scheme; a dot in the list's MAT-2/HC7 column, not a level
    Products
    Adhesives & Sealants (VOC)
    Scope
    Dot only in the Adhesives & Sealants MAT-2/HC7 column. Covers adhesives and sealants applied on site within the conditioned area.
    Conditions
    • usable for VOC or formaldehyde criteria only
    • certificate must be for the final product; a component certificate needs a Technical Question
    Source
    Homestar v5 · HC7 · List p. 1; HC7 p. 1, 2

Not named by: WELL v2.

Read EMICODE’s requirements →

GECA

Where it earns points or counts, rating tool by rating tool. About GECA

Credit names, credential names and conditions are in each rating tool's or policy's own words, shown where its publisher's terms allow.

Homestar v5Rating tool

  • EN3 Sustainable Materials, approved eco-labels; Recognised list, GECA Level A Recognition, MAT-1/EN3 columns

    Status
    Accepted with conditions
    Named as
    GECA
    Edition named
    PCv2.2i-2012; 04-2011 v2; 40-2008 v1.1; FFM v3.0-2017; 28-2010 v2.1; 25-2011 v2; 50-2011 v2; BIMv2.0-2018; SSPv1.0-2019
    Level
    Level A Recognition · eco-label recognition level; Level A eco-label = 1.5 points
    On what basis
    points per material category
    Products
    Not shown under New Zealand Green Building Council's terms
    Scope
    No GECA entry for Concrete.
    Conditions
    • product certified to the GECA standard listed for its category
    • certificate must be for the final product; a component certificate needs a Technical Question
    Source
    Homestar v5 · EN3 · List p. 1; EN3 p. 9
  • EN3 Sustainable Materials, approved eco-labels; Recognised list, GECA Level B Recognition, EWP & Timber Product Sustainability (MAT-1/EN3)

    Status
    Accepted with conditions
    Named as
    GECA
    Edition named
    GECA FF v3.0-2017 'Furniture and Fittings'
    Level
    Level B Recognition · eco-label recognition level; Level B eco-label = 1 point
    On what basis
    points per material category
    Products
    Engineered Wood Products (EWP) & Timber
    Scope
    Only Level B GECA entry; EN3 only (no HC7 entry).
    Conditions
    • product certified to GECA FF v3.0-2017
    • engineered wood products and timber only
    • certificate must be for the final product
    Source
    Homestar v5 · EN3 · List p. 1; EN3 p. 9
  • HC7 Healthy Materials, methods (1)-(4); Recognised list, GECA Level A Recognition, MAT-2/HC7 columns

    Status
    Accepted with conditions
    Named as
    GECA
    Edition named
    AFSv4.0-2014; PCv2.2i-2012; FFM v3.0-2017; 28-2010 v2.1; 04-2011 v2; 25-2011 v2; 50-2011 v2; 40-2008 v1.1
    On what basis
    product within the VOC limits specified by the recognised eco-label; listed as Level A Recognition
    Products
    Adhesives & Sealants: GECA AFSv4.0-2014; Applied Coatings: GECA PCv2.2i-2012; EWP: GECA FFM v3.0-2017, 28-2010 v2.1, 04-2011 v2, 25-2011 v2; Flooring: GECA 50-2011 v2, 25-2011 v2, 40-2008 v1.1, 04-2011v2
    Scope
    Interior of the dwelling only.
    Conditions
    • usable for VOC or formaldehyde criteria only
    • product certified to the GECA standard listed for its category
    • certificate must be for the final product; a component certificate needs a Technical Question
    Source
    Homestar v5 · HC7 · List p. 1; HC7 p. 1, 2

WELL v2Rating tool

  • X01 Material Restrictions, Part 3 Restrict Lead, 1: Paints and electronics (paints)

    Status
    Accepted as an ISO 14024 Type I ecolabel (own statement)
    Named as
    GECA
    Edition named
    Not stated by the tool
    Products
    Paints applied as finishes
    Scope
    Paint path only.
    The rule
    Not shown under International WELL Building Institute pbc's terms
    Source
    WELL v2 · X01 (materials/feature/1)
  • X11 Cleaning Products and Protocols, Part 2 Select Preferred Cleaning Products

    Status
    Outside this credit's scope
    Named as
    GECA
    Edition named
    Not stated by the tool
    Products
    Cleaning products
    Scope
    Cleaning products, not construction products.
    Source
    WELL v2 · X11 (materials/feature/11)

Read GECA’s requirements →

Health Product Declaration

Where it earns points or counts, rating tool by rating tool. About Health Product Declaration

Credit names, credential names and conditions are in each rating tool's or policy's own words, shown where its publisher's terms allow.

WELL v2Rating tool

  • X07 Materials Transparency, Part 1 Select Products With Disclosed Ingredients

    Status
    Accepted with conditions
    Named as
    Health Product Declaration
    Edition named
    Not stated by the tool
    Products
    Permanently installed products, furniture, task and floor lamps
    Scope
    Project threshold: at least 25 distinct products.
    Conditions
    Not shown under International WELL Building Institute pbc's terms
    Source
    WELL v2 · X07 (materials/feature/7)
  • X07 Materials Transparency, Part 2 Select Products With Enhanced Ingredient Disclosure

    Status
    Accepted with conditions
    Named as
    Health Product Declaration
    Edition named
    Not stated by the tool
    Products
    Permanently installed products, furniture, task and floor lamps
    Scope
    Project threshold: at least 15 distinct products.
    Conditions
    Not shown under International WELL Building Institute pbc's terms
    Source
    WELL v2 · X07 (materials/feature/7)
  • X07 Materials Transparency, Part 3 Select Products With Third-Party Verified Ingredients

    Status
    Accepted with conditions
    Named as
    Health Product Declaration
    Edition named
    Not stated by the tool
    Products
    Permanently installed products, furniture, task and floor lamps
    Scope
    Project threshold: at least 15 distinct products.
    Conditions
    Not shown under International WELL Building Institute pbc's terms
    Source
    WELL v2 · X07 (materials/feature/7)

Not named by: Homestar v5.

Read Health Product Declaration’s requirements →

PEFC

Where it earns points or counts, rating tool by rating tool. About PEFC

Credit names, credential names and conditions are in each rating tool's or policy's own words, shown where its publisher's terms allow.

Homestar v5Rating tool

  • EN2 Embodied Carbon, Assessment, Biogenic carbon

    Status
    Accepted with conditions
    Named as
    PEFC
    Edition named
    Not stated by the tool
    On what basis
    biogenic carbon sequestration may be counted in the modules A-D lifecycle footprint
    Products
    Timber and engineered wood products
    Scope
    No sequestration in A1-A5 emissions used for points 2-6.
    Conditions
    • the timber or engineered wood must have achieved EN3 points for PEFC
    • sequestration counts only in the overall A-D footprint, not in A1-A5
    • evidence of responsible sourcing in the materials specification
    Source
    Homestar v5 · EN2 · EN2 p. 4
  • EN3 Sustainable Materials, means of compliance 'Programme for the Endorsement of Forest Certification (PEFC)'

    Status
    Accepted
    Named as
    PEFC
    Edition named
    Not stated by the tool
    Level
    1.5 · points per material category
    On what basis
    material category with at least 50% “compliant” (Homestar’s word) content
    Products
    Structural and framing timber, other solid timber, engineered wood, timber cladding, flooring
    Scope
    The list shows 'PEFC Certified' in the EWP & Timber and Flooring EN3 columns only. List note d: final-product certificates only.
    Source
    Homestar v5 · EN3 · EN3 p. 9; List p. 1

Not named by: WELL v2.

Read PEFC’s requirements →

Steel Sustainability Australia

Where it earns points or counts, rating tool by rating tool. About Steel Sustainability Australia

Credit names, credential names and conditions are in each rating tool's or policy's own words, shown where its publisher's terms allow.

None of the rating tools or policies selected names Steel Sustainability Australia. That is not a statement that none accepts it.

Read Steel Sustainability Australia’s requirements →