GWP reference value for thermal insulation products

Blue Angel·clause 3.3·p.20

The requirement

The publisher’s words are shown on request, below the limits.

What the product must meet

Limits held for this clause

Parameter / contextOperatorLimitUnit
(all insulation materials): ≤ 6.0 kg CO₂ eq. per m² (where R = 1 m²∙K/W)23≤6unit not recorded
ded ceilings in the system: ≤ 10.0 kg CO₂ eq. per m² (where R = 1 m²∙K/W or≤10unit not recorded

The document states how these relate: these limits apply in steps, by level or by band.

Compare this limit across schemes

The limit was read from the clause wording and checked by a reader.

Exemptions
High-performance insulation products with a thermal conductivity of < 0.020 [W/mK] are excluded from this requirement (no maximum value requirement)

The publisher’s words

The publisher lets each reader see 3 of this document’s clauses a day.

This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.

How it is proven

Evidence required
The applicant shall declare compliance with the requirements in Annex 1 and declare the GWP reference value (the GWP for the manufacturing and disposal phase, sum of the GWP information for modules A1 to A3 and C1 to C4 of the EPD, of the product for a 1 m² reference application with an R-value of 1 m²∙K/W) in Annex 1-P and confirm compliance with the respective applica- ble permitted material value for the GWP reference. If the EPD is not yet available when the application is submitted, the GWP reference value is submitted at a later time together with the EPD as soon as it is available, without being asked to do so.
Who checks it
Applicant declares — a signed statement from the applicant

How Klar Cite classifies it

Klar Cite’s reading of the clause, not the scheme’s own claim.

What it asks
Meet — a limit, condition or outcome the product must satisfy
Standing
Required — must be met for the credential
Impact area
Climate Health — the CMF area the clause addresses

Cite this clause

Blue Angel · DE-UZ 132 Low Emission Thermal Insulation · version DE-UZ 132 · clause 3.3 · page 20 · build 2026-10-05-0439 · https://klarcite.com/r/f2db933209f274c3

Source document

Record details

Page 20, 3.3 Global Warming Potential (GWP) reference value. Read in build 2026-10-05-0439, harvested 2026-10-05.

uid f2db933209f274c3 · document 3d7e13fc3f89d869 · fidelity verbatim · published 2026-07