Antimony limits in virgin polyester fibres

GECA·clause MS-3.5·p.23

The requirement

The publisher’s words are shown on request, below the limits.

What the product must meet

Limits held for this clause

Parameter / contextOperatorLimitUnit
mass concentration≤260ppm

Compare this limit across schemes

The limit was read from the clause wording.

The publisher’s words

The publisher lets each reader see 4 of this document’s clauses a day.

This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.

How it is proven

Evidence required
Either a declaration of non-use of antimony, production information showing the amount of antimony in the virgin polyester, or a test report using the following test method: direct determination by Atomic Adsorption (AA) Spectrometry. The test shall be carried out on the raw fibre.
Who checks it
Independent body verifies — a certifier, auditor or verifier with no stake

How Klar Cite classifies it

Klar Cite’s reading of the clause, not the scheme’s own claim.

What it asks
Meet — a limit, condition or outcome the product must satisfy
Standing
Required — must be met for the credential
Impact area
Human Health — the CMF area the clause addresses

Cite this clause

GECA · Building Insulation Materials · version BIM Gen 3.0 · clause MS-3.5 · page 23 · build 2026-10-05-0439 · https://klarcite.com/r/fecc62bef8d59d2b

Source document

Record details

Page 23, MS-3.5 ANTIMONY LIMITS. Read in build 2026-10-05-0439, harvested 2026-10-05.

uid fecc62bef8d59d2b · document 6a818ca4f3f10cf8 · fidelity verbatim · published 2026-06

Other clauses in this standard