N-nitrosamines emission limits for rubber products
GECA·clause MS-3.5·p.26
The requirement
The publisher’s words are shown on request, below the limits.
What the product must meet
Limits held for this clause
| Parameter / context | Operator | Limit | Unit |
|---|---|---|---|
| air concentration | ≤ | 0.001 | mg/m³ |
The clause carries more than one limit; only the first is held as a number.
Compare this limit across schemes
The limit was read from the clause wording.
The publisher’s words
The publisher lets each reader see 5 of this document’s clauses a day.
This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.
How it is proven
- Evidence required
- DoC MS-3.5.1: Test report based on chamber method (ISO 16000-9 or based on TRGS 552:2018 or other equivalent methods) and according to above procedures demonstrating compliance with the threshold mentioned in above criterion.
- Who checks it
- Independent body verifies — a certifier, auditor or verifier with no stake
How Klar Cite classifies it
Klar Cite’s reading of the clause, not the scheme’s own claim.
- What it asks
- Meet — a limit, condition or outcome the product must satisfy
- Standing
- Required — must be met for the credential
- Impact area
- Human Health — the CMF area the clause addresses
Cite this clause
GECA · Floor Coverings · version FC Gen 3.0 · clause MS-3.5 · page 26 · build 2026-10-05-0439 · https://klarcite.com/r/a77c68cfff73e9a8
Record details
Page 26, MS-3.5 N-NITROSAMINES. Read in build 2026-10-05-0439, harvested 2026-10-05.
uid a77c68cfff73e9a8 · document 8c35f185de6c5323 · fidelity verbatim · published 2026-06