Reverberation time compliance

LEED·clause EQ CREDIT: ACOUSTIC PERFORMANCE NC, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY Reverberation Time·p.140

Klar Cite’s name for this clause. The publisher’s own heading may not be shown.

The requirement

LEED v4.1 Building Design and Construction Rating System clause EQ CREDIT: ACOUSTIC PERFORMANCE NC, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY Reverberation Time — words not shown. Read it at the source. The held copy is a single-user licence and does not extend to republishing its clauses.

The clause is held and verified. Only its words are withheld.

Klar Cite classification — not the standard’s words

Addresses: room acoustics requirements

written by a model, checked against the clause

Read it at the source

What the product must meet

The document’s own listing

Hotel/motel Individual room or suite: < 0.6 Meeting or banquet room: < 0.8 Office building Executive or private office: < 0.6 Conference room: < 0.6 Teleconference room: < 0.6 Open-plan office without sound masking: < 0.8 Open-plan office with sound masking: 0.8 Courtroom Unamplified speech: < 0.7 Amplified speech: < 1.0 Drama theaters, concert and recital halls: Varies by application Testing or research with minimal speech communication: < 1.0 Extensive phone use and speech communication: < 0.6 General assembly with critical music program: Varies by application Library: < 1.0 Indoor stadium, gymnasium Gymnasium and natatorium: < 2.0 Large-capacity space with speech amplification: < 1.5

The document’s own compact listing of the limits, as harvested.

Applies to
New Construction, Data Centers, Warehouses & Distribution Centers, Hospitality

How it is proven

Who checks it
Independent body verifies — a certifier, auditor or verifier with no stake

How Klar Cite classifies it

Klar Cite’s reading of the clause, not the scheme’s own claim.

What it asks
Meet — a limit, condition or outcome the product must satisfy
Standing
Required — must be met for the credential
Refers to
Table 2; Table 9 — places elsewhere in the document

Cite this clause

LEED · LEED v4.1 Building Design and Construction Rating System · version v4.1 · clause EQ CREDIT: ACOUSTIC PERFORMANCE NC, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY Reverberation Time · page 140 · build 2026-10-05-0439 · https://klarcite.com/r/dc32d346c041e8d8

Source document

Record details

Page 140. Read in build 2026-10-05-0439, harvested 2026-10-05.

uid dc32d346c041e8d8 · document 735b8f7d282ce93c · fidelity verbatim · published 2025-02-01