Reverberation time compliance
LEED·clause EQ CREDIT: ACOUSTIC PERFORMANCE NC, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY Reverberation Time·p.140
Klar Cite’s name for this clause. The publisher’s own heading may not be shown.
The requirement
LEED v4.1 Building Design and Construction Rating System clause EQ CREDIT: ACOUSTIC PERFORMANCE NC, DATA CENTERS, WAREHOUSES & DISTRIBUTION CENTERS, HOSPITALITY Reverberation Time — words not shown. Read it at the source. The held copy is a single-user licence and does not extend to republishing its clauses.
The clause is held and verified. Only its words are withheld.
Klar Cite classification — not the standard’s words
Addresses: room acoustics requirements
written by a model, checked against the clause
What the product must meet
The document’s own listing
Hotel/motel Individual room or suite: < 0.6 Meeting or banquet room: < 0.8 Office building Executive or private office: < 0.6 Conference room: < 0.6 Teleconference room: < 0.6 Open-plan office without sound masking: < 0.8 Open-plan office with sound masking: 0.8 Courtroom Unamplified speech: < 0.7 Amplified speech: < 1.0 Drama theaters, concert and recital halls: Varies by application Testing or research with minimal speech communication: < 1.0 Extensive phone use and speech communication: < 0.6 General assembly with critical music program: Varies by application Library: < 1.0 Indoor stadium, gymnasium Gymnasium and natatorium: < 2.0 Large-capacity space with speech amplification: < 1.5
The document’s own compact listing of the limits, as harvested.
- Applies to
- New Construction, Data Centers, Warehouses & Distribution Centers, Hospitality
How it is proven
- Who checks it
- Independent body verifies — a certifier, auditor or verifier with no stake
How Klar Cite classifies it
Klar Cite’s reading of the clause, not the scheme’s own claim.
- What it asks
- Meet — a limit, condition or outcome the product must satisfy
- Standing
- Required — must be met for the credential
- Refers to
- Table 2; Table 9 — places elsewhere in the document