Indoor air quality testing

LEED·clause EQ CREDIT: INDOOR AIR QUALITY ASSESSMENT Option 2 Path 1·p.65

Klar Cite’s name for this clause. The publisher’s own heading may not be shown.

The requirement

LEED v4.1 Interior Design and Construction Rating System clause EQ CREDIT: INDOOR AIR QUALITY ASSESSMENT Option 2 Path 1 — words not shown. Read it at the source. The held copy is a single-user licence and does not extend to republishing its clauses.

The clause is held and verified. Only its words are withheld.

Klar Cite classification — not the standard’s words

Addresses: indoor air contaminant concentrations

written by a model, checked against the clause

Read it at the source

What the product must meet

The document’s own listing

Carbon monoxide: 9 ppm; no more than 2 ppm above outdoor levels PM 10: 50 μg/m3 PM 2.5: 12 μg/m3 or 35 μg/m3** Ozone: 0.07 ppm

The document’s own compact listing of the limits, as harvested.

Applies to
Commercial Interiors, Retail, Hospitality

How it is proven

Who checks it
Independent body verifies — a certifier, auditor or verifier with no stake

How Klar Cite classifies it

Klar Cite’s reading of the clause, not the scheme’s own claim.

What it asks
Meet — a limit, condition or outcome the product must satisfy
Standing
Required — must be met for the credential
Impact area
Human Health — the CMF area the clause addresses
Pathway
Option PATH 1 — the document offers alternatives, and this is one
Refers to
Table 1 — places elsewhere in the document

Cite this clause

LEED · LEED v4.1 Interior Design and Construction Rating System · version v4.1 · clause EQ CREDIT: INDOOR AIR QUALITY ASSESSMENT Option 2 Path 1 · page 65 · build 2026-10-05-0439 · https://klarcite.com/r/60db798603a65480

Source document

Record details

Page 65. Read in build 2026-10-05-0439, harvested 2026-10-05.

uid 60db798603a65480 · document c462df901618d62d · fidelity verbatim · published 2024-02-01