Indoor Air Quality

Blue Angel·clause 3.2.1·p.12

The requirement

The publisher’s words are shown on request, below the limits.

What the product must meet

The document’s own listing

Total organic compounds within the retention ≤ 1000 µg/m³ ≤ 300 µg/m³ Carcinogenic substances ≤ 10 µg/m³ ≤ 1 µg/m³ total per single value Formaldehyde - ≤ 60 µg/m³ (0.05 ppm)

The document’s own compact listing of the limits, as harvested.

The publisher’s words

The publisher lets each reader see 3 of this document’s clauses a day.

This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.

How it is proven

Evidence required
Test report according to Part II of the “Grundsätze des DIBt zur gesundheitlichen Bewertung von Bauprodukten in Innenräumen“ based on DIN EN 16516 prepared by a testing laboratory accredited for this test by BAM.
Who checks it
Independent body verifies — a certifier, auditor or verifier with no stake

How Klar Cite classifies it

Klar Cite’s reading of the clause, not the scheme’s own claim.

What it asks
Meet — a limit, condition or outcome the product must satisfy
Standing
Required — must be met for the credential
Impact area
Human Health — the CMF area the clause addresses
Refers to
Table 2 — places elsewhere in the document

Cite this clause

Blue Angel · DE-UZ 156 Flooring Underlays · version DE-UZ 156 · clause 3.2.1 · page 12 · build 2026-10-05-0439 · https://klarcite.com/r/3297393869cdd349

Source document

Record details

Page 12, 3.2 Use. Read in build 2026-10-05-0439, harvested 2026-10-05.

uid 3297393869cdd349 · document 699ddaee9d5e5592 · fidelity verbatim · published 2019

Other clauses in this standard