Compliance verification for chlorophenols in latex foam
Blue Angel·clause 3.7.2·pp.15-16
The requirement
The publisher’s words are shown on request, below the limits.
What the product must meet
Limits held for this clause
| Parameter / context | Operator | Limit | Unit |
|---|---|---|---|
| mass concentration | < | 1 | mg/kg |
The clause carries more than one limit; only the first is held as a number.
Compare this limit across schemes
The limit was read from the clause wording.
The publisher’s words
The publisher lets each reader see 4 of this document’s clauses a day.
This is the publisher’s condition for Klar Cite showing its words; the limits, the citation and everything else on this page are free to read. Showing the wording counts one clause.
How it is proven
- Evidence required
- The applicant shall submit a test report for a test carried out in accordance with one of the following methods: Milling and weighing of sample. Sampling performed using headspace sampling. Analysis using gas chromatography, verification using the flame ionisation detector method. 15/27 DE-UZ
- Who checks it
- Independent body verifies — a certifier, auditor or verifier with no stake
How Klar Cite classifies it
Klar Cite’s reading of the clause, not the scheme’s own claim.
- What it asks
- Disclose — information the applicant must provide
- Standing
- Required — must be met for the credential
- Impact area
- Human Health — the CMF area the clause addresses
Cite this clause
Blue Angel · DE-UZ 117 Low Emission Upholstered Furniture · version DE-UZ 117 · clause 3.7.2 · page 15-16 · build 2026-10-05-0439 · https://klarcite.com/r/2415adc33e706eda
Record details
Page 15-16. Read in build 2026-10-05-0439, harvested 2026-10-05.
uid 2415adc33e706eda · document d4d6a55b4646cf5d · fidelity close quote · published 2018